Frequently Asked Questions

Can’t find an answer? Call us at +1-425-488-1100 or email with contact su*****@********sa.com

Item #1

What is your HMI software called?

The software used to program all current Weintek HMIs is called EasyBuilder Pro or EB pro; legacy units may use EasyBuilder 8000 or EasyBuilder 500.

The software used to program all current Weintek HMIs is called EasyBuilder Pro or EB pro; legacy units may use EasyBuilder 8000 or EasyBuilder 500.

Why is EasyBuilder Pro free?

There’s a common misconception that free software isn’t high-quality, but that’s not in any way true for ours. EasyBuilder Pro is loaded with advanced features like SQL, MQTT, scripting, and the ability to design custom UI components using JavaScript. In addition, we support over 400 industrial communication protocols.

There’s a common misconception that free software isn’t high-quality, but that’s not in any way true for ours. EasyBuilder Pro is loaded with advanced features like SQL, MQTT, scripting, and the ability to design custom UI components using JavaScript. In addition, we support over 400 industrial communication protocols.

What features does your software support?

“EasyBuilder Pro is an IDE designed for programming Weintek HMIs and Gateways. Here is short list of features that are available within EasyBuilder Pro: Services: Timer, Scheduler, BACnet Schedule, Data sampling (logging), Event (Alarm) (logging), Operation (logging), MQTT (AWS, Google IoT, Azure), OPC UA, MS SQL, MySQL, FTP File Transfer, Data Transfer, Macros. UI Objects […]

“EasyBuilder Pro is an IDE designed for programming Weintek HMIs and Gateways. Here is short list of features that are available within EasyBuilder Pro:

Services:
Timer, Scheduler, BACnet Schedule, Data sampling (logging), Event (Alarm) (logging), Operation (logging), MQTT (AWS, Google IoT, Azure), OPC UA, MS SQL, MySQL, FTP File Transfer, Data Transfer, Macros.

UI Objects (read only):
Bit Lamp, Word Lamp

UI Objects (write only):
Set Bit, Set Word.

UI Objects (read / write):
Toggle Switch, Multi-State Switch, Slider, Option List, Numeric entry, ASCII entry.

UI Objects (data display):
Bar Graph, XY Plot, Data Block Display, Meter Display, Event Bar Chart, VNC Viewer, PDF reader, Picture View, Media player, IP / USB Camera, PLC Web Browser.

UI Objects (animation):
Animation, Moving shape.

In addition, EasyBuilder Pro also allows users to create objects with their own function using JavaScript within a JS Object.”

Where can I download software?

To download the latest version of EasyBuilder Pro, EasyAccess 2.0, or other Weintek software, please create an account on our forum at forum.weintekusa.com.

To download the latest version of EasyBuilder Pro, EasyAccess 2.0, or other Weintek software, please create an account on our forum at forum.weintekusa.com.

Where can I download legacy versions of EasyBuilder Pro?

To download legacy versions of EasyBuilder Pro, please contact us at su*****@********sa.com for a direct link, as these versions are no longer listed on our website.

To download legacy versions of EasyBuilder Pro, please contact us at su*****@********sa.com for a direct link, as these versions are no longer listed on our website.

How do I upload an HMI project?

To upload an HMI project, select [File] → [Upload] in EasyBuilder Pro. Please ensure you use the correct upload password, as the process may fail otherwise. If the project was created by an OEM vendor, we recommend contacting the vendor to obtain the proper password. Note that our support team cannot bypass password restrictions set […]

To upload an HMI project, select [File] → [Upload] in EasyBuilder Pro. Please ensure you use the correct upload password, as the process may fail otherwise. If the project was created by an OEM vendor, we recommend contacting the vendor to obtain the proper password. Note that our support team cannot bypass password restrictions set by the project developer.

How do I decrypt a project file?

Some developers may encrypt the application file with a password prior to deployment. In this case, you will need to contact the original project developer to obtain the password. Note that our support team cannot bypass password restrictions set by the project developer.

Some developers may encrypt the application file with a password prior to deployment. In this case, you will need to contact the original project developer to obtain the password. Note that our support team cannot bypass password restrictions set by the project developer.

Which device driver should I use?

This question can be difficult to answer definitively, as Weintek frequently updates and adds new drivers. To find the correct driver for your device, please visit the device driver page on our forum: https://forum.weintekusa.com/pub/supported-devices

This question can be difficult to answer definitively, as Weintek frequently updates and adds new drivers. To find the correct driver for your device, please visit the device driver page on our forum: https://forum.weintekusa.com/pub/supported-devices

Can I download my project to a different HMI model?

A project created for any cMT or cMT X model can be converted to work on another cMT or cMT X model. However, a project file designed for a cMT or cMT X model cannot be converted for use on iE, iP, XE, eMT, or mTV models.

A project created for any cMT or cMT X model can be converted to work on another cMT or cMT X model. However, a project file designed for a cMT or cMT X model cannot be converted for use on iE, iP, XE, eMT, or mTV models.

Where can I learn more about your software?

We offer numerous step-by-step tutorials on our forum at forum.weintekusa.com and on our YouTube channel: https://www.youtube.com/@WeintekUSAInc.

We offer numerous step-by-step tutorials on our forum at forum.weintekusa.com and on our YouTube channel: https://www.youtube.com/@WeintekUSAInc.

What is the main difference between standard and advanced HMIs?

While overall performance remains the same, our advanced HMIs (e.g., cMT3000X ) offer expanded capabilities, including support for the built-in PLC web browser, SQL features, an OPC UA server, and CAN bus on applicable models.

While overall performance remains the same, our advanced HMIs (e.g., cMT3000X ) offer expanded capabilities, including support for the built-in PLC web browser, SQL features, an OPC UA server, and CAN bus on applicable models.

Do any HMI models support connections via HDMI?

Yes, the cMT-FHDX-820 can connect to an external display via HDMI.

Yes, the cMT-FHDX-820 can connect to an external display via HDMI.

What operating system do the HMIs use?

Weintek HMIs run a customized Linux OS designed to support applications created with EasyBuilder Pro. Some models, such as our web panels and cMT Viewer panels, operate as thin-client devices and run a built-in web browser or the cMT Viewer app, respectively.

Weintek HMIs run a customized Linux OS designed to support applications created with EasyBuilder Pro. Some models, such as our web panels and cMT Viewer panels, operate as thin-client devices and run a built-in web browser or the cMT Viewer app, respectively.

How can I upgrade my HMI’s firmware?

Weintek USA does not provide direct download links for HMI firmware because our support team must verify the correct firmware for each unit’s chipset; however, most issues can be resolved by simply updating EasyBuilder Pro. This will also update the HMI’s runtime. If EasyBuilder Pro indicates that a different firmware revision is needed to use […]

Weintek USA does not provide direct download links for HMI firmware because our support team must verify the correct firmware for each unit’s chipset; however, most issues can be resolved by simply updating EasyBuilder Pro. This will also update the HMI’s runtime. If EasyBuilder Pro indicates that a different firmware revision is needed to use a specific feature, please contact su*****@********sa.com for assistance with upgrading the unit.

Does Weintek sell panel PCs or IPCs?

Weintek does not offer any units with a Windows OS, commonly called panel PCs or IPCs. Instead, our HMIs use a Linux-based OS optimized for running projects developed with EasyBuilder Pro. Additionally, we offer HMIs that function as thin-client devices, running either a built-in web browser or the cMT Viewer app.

Weintek does not offer any units with a Windows OS, commonly called panel PCs or IPCs. Instead, our HMIs use a Linux-based OS optimized for running projects developed with EasyBuilder Pro. Additionally, we offer HMIs that function as thin-client devices, running either a built-in web browser or the cMT Viewer app.

Is Weinview the same as Weintek?

No, Weinview distributes products to the Chinese market. We do not sell Weinview units, those units are sold only by [Weinview](http://www.weinview.cn).

No, Weinview distributes products to the Chinese market. We do not sell Weinview units, those units are sold only by [Weinview](http://www.weinview.cn).

What units have a built-in PLC?

Every cMT X HMI sold by Weintek USA can function as a combined PLC-HMI system when equipped with the optional CODESYS SoftPLC runtime.

Every cMT X HMI sold by Weintek USA can function as a combined PLC-HMI system when equipped with the optional CODESYS SoftPLC runtime.

What is a headless HMI?

A headless HMI is an HMI device that operates without a built-in display. It is designed to be controlled and monitored remotely using a web browser or application. Weintek’s headless HMI models include the cMT-FHDX-820, cMT-SVRX-820, and cMT-SVRX-822.

A headless HMI is an HMI device that operates without a built-in display. It is designed to be controlled and monitored remotely using a web browser or application. Weintek’s headless HMI models include the cMT-FHDX-820, cMT-SVRX-820, and cMT-SVRX-822.

What is the HMIs password?

The out-of-the-box password is 111111. If you are working with an HMI that you did not program or install we recommend contacting the installer to determine the password.

The out-of-the-box password is 111111. If you are working with an HMI that you did not program or install we recommend contacting the installer to determine the password.

How do I upload an HMI project?

To upload an HMI project, select [File] → [Upload] in EasyBuilder Pro. Please ensure you use the correct upload password, as the process may fail otherwise. If the project was created by an OEM vendor, we recommend contacting the vendor to obtain the proper password. Note that our support team cannot bypass password restrictions set […]

To upload an HMI project, select [File] → [Upload] in EasyBuilder Pro. Please ensure you use the correct upload password, as the process may fail otherwise. If the project was created by an OEM vendor, we recommend contacting the vendor to obtain the proper password. Note that our support team cannot bypass password restrictions set by the project developer.

Why Codesys?

CODESYS is an exceptional PLC IDE that is the framework of many PLC IDEs on the market. If you have used Schneider, Beckhoff, or Wago’s PLC software you will find the CODESYS IDE quite familiar. In addition, the control logic complies with IEC 61131-3 which means that you can use ladder logic, function-block diagrams, sequential […]

CODESYS is an exceptional PLC IDE that is the framework of many PLC IDEs on the market. If you have used Schneider, Beckhoff, or Wago’s PLC software you will find the CODESYS IDE quite familiar. In addition, the control logic complies with IEC 61131-3 which means that you can use ladder logic, function-block diagrams, sequential function charts, instruction lists, or structured text within your application.

Where can I download Codesys?

Weintek’s R&D has validated CODESYS IDE v3.5.15.50 and related drivers for use with Weintek’s CODESYS-equipped HMIs or the cMT-CTRL-01. To download, please download CODESYS (Link), and then download and install Weintek’s CODESYS package (Link) After that you can review a short tutorial to create your first CODESYS application (Link)

Weintek’s R&D has validated CODESYS IDE v3.5.15.50 and related drivers for use with Weintek’s CODESYS-equipped HMIs or the cMT-CTRL-01. To download, please download CODESYS (Link), and then download and install Weintek’s CODESYS package (Link) After that you can review a short tutorial to create your first CODESYS application (Link)

Can I remove Weintek’s Codesys after activation?

No, once activated the built-in CODESYS cannot be deactivated.

No, once activated the built-in CODESYS cannot be deactivated.

Can I create my Codesys project within EasyBuilder Pro?

No, you will need to use the Codesys IDE (see above) to create your Codeys project. The HMI can be programmed for visualization using EasyBuilder Pro. Note: Weintek’s CODESYS can only access Ethernet LAN-1 and CANBus port (if a CANBus port is embedded).

No, you will need to use the Codesys IDE (see above) to create your Codeys project. The HMI can be programmed for visualization using EasyBuilder Pro. Note: Weintek’s CODESYS can only access Ethernet LAN-1 and CANBus port (if a CANBus port is embedded).

Can a CODESYS-activated HMI still use EasyAccess 2.0?

Yes, an HMI with activated CODESYS can still use our EasyAccess 2.0 remote access service. To use this service the HMI must be connected to the internet via LAN 2 as in the image below:

Yes, an HMI with activated CODESYS can still use our EasyAccess 2.0 remote access service. To use this service the HMI must be connected to the internet via LAN 2 as in the image below:

Can an HMI with CODESYS connect to devices in EasyBuilder Pro?

Yes, an HMI with CODESYS activated can still communicate with PLCs using any of the 400+ drivers available in EasyBuilder Pro—except for CAN bus on certain models. Once CODESYS is activated, it takes control of the CAN bus port. However, RS-232 and RS-485 ports remain available, and Ethernet-based PLCs can still be accessed via LAN […]

Yes, an HMI with CODESYS activated can still communicate with PLCs using any of the 400+ drivers available in EasyBuilder Pro—except for CAN bus on certain models. Once CODESYS is activated, it takes control of the CAN bus port. However, RS-232 and RS-485 ports remain available, and Ethernet-based PLCs can still be accessed via LAN 2, since LAN 1 is reserved for CODESYS.

How do I connect to Weintek’s Codesys?

Codesys has complete control over LAN-1, please make sure that your PC is connected to LAN-1 or that you have “Codesys Login” enabled on the HMI. While “Codesys Login” is enabled, you can connect to the HMI and Codesys using LAN-2. To enable Codesys Login, please read this post: How to enable Codesys login Once […]

Codesys has complete control over LAN-1, please make sure that your PC is connected to LAN-1 or that you have “Codesys Login” enabled on the HMI. While “Codesys Login” is enabled, you can connect to the HMI and Codesys using LAN-2. To enable Codesys Login, please read this post: How to enable Codesys login

Once finished specify the HMI’s LAN-2 IP within the “Device” communication setting in your Codesys project. Note: Codesys has no control over LAN-2.

What protocols does Weintek’s Codesys support?

Currently Weintek’s built-in Codesys supports the following protocols: Modbus TCP/IP (master) EtherCAT (master) CANopen (master) Prerequisite: CANopen is only available on Weintek CMT-X HMIs that are equipped with a CANBus port. EtherNet/IP (master) PROFINET (master) Note: Weintek’s Codesys cannot act as a Modbus TCP Slave by adding a single Modbus Slave device in the device […]

Currently Weintek’s built-in Codesys supports the following protocols:

Modbus TCP/IP (master)
EtherCAT (master)
CANopen (master)
Prerequisite: CANopen is only available on Weintek CMT-X HMIs that are equipped with a CANBus port.
EtherNet/IP (master)
PROFINET (master)

Note: Weintek’s Codesys cannot act as a Modbus TCP Slave by adding a single Modbus Slave device in the device tree, but users can utilize a specific Function Block of the ModbusTCPSlave library to achieve the objective.

Trying to add any Slave or Adapter Device without under a Master Device will not work.

Can Weintek’s Codesys communicate with a third-party device?

Certainly! You may use any of the protocols mentioned above to communicate with an external device of your choice.

Certainly! You may use any of the protocols mentioned above to communicate with an external device of your choice.

What communication drivers should I use within Codesys?

We recommend that you use device drivers included with Weintek’s Codesys package: Device Version CANbus 3.5.15.0 CANopen manager 3.5.15.0 Ethernet adapter (added under Ethernet IP Scanner) 3.5.15.0 Ethernet IP Scanner 3.5.15.50 Modbus TCP maste 3.5.15.0 EtherCAT master 3.5.12.0 PROFINET master 3.5.13.0 Note: You may need to select “Display all versions” within the “Add Device” dialog […]

We recommend that you use device drivers included with Weintek’s Codesys package:

Device Version
CANbus 3.5.15.0
CANopen manager

3.5.15.0
Ethernet adapter (added under Ethernet IP Scanner)

3.5.15.0
Ethernet IP Scanner 3.5.15.50
Modbus TCP maste 3.5.15.0
EtherCAT master 3.5.12.0
PROFINET master 3.5.13.0

Note: You may need to select “Display all versions” within the “Add Device” dialog to select the appropriate driver. For more information, please read this post: How to update device drivers

How many devices can Weintek’s Codesys communicate with?

Modbus TCP/IP 32 devices EtherCAT 65,535 devices CANopen 126 devices EtherNet/IP 32 devices PROFINET 32 devices

Modbus TCP/IP 32 devices
EtherCAT

65,535 devices
CANopen

126 devices
EtherNet/IP 32 devices
PROFINET 32 devices

What features cannot be used with Weintek’s Codesys runtime?

OPC UA features Network Variable List Alarm Configuration (Alarm Manager) Redundancy Configuration CODESYS TargetVisu CODESYS WebVisu CODESYS HMI SoftMotion CODESYS IIoT Libraries SL CODESYS OPC UA Client SL CODESYS OPC UA Server SL CODESYS Safety for EtherCAT Safety Module SL Other add-ons Trying to install other licenses from the CODESYS website will not work.

OPC UA features
Network Variable List
Alarm Configuration (Alarm Manager)
Redundancy Configuration

CODESYS TargetVisu
CODESYS WebVisu
CODESYS HMI

SoftMotion

CODESYS IIoT Libraries SL
CODESYS OPC UA Client SL
CODESYS OPC UA Server SL
CODESYS Safety for EtherCAT Safety Module SL
Other add-ons

Trying to install other licenses from the CODESYS website will not work.

What libraries does Weintek’s Codesys support?

“Weintek’s built-in Codesys is compatible with wide range of built-in libraries. However, certain libraries that require OS support are not compatible with the device runtime. The libraries within the table below are compatible with Weintek’s built-in Codesys. Libraries that do not require OS support are also compatible with Weintek’s built-in Codesys.; e.g. OSCAT Basic, Util […]

“Weintek’s built-in Codesys is compatible with wide range of built-in libraries. However, certain libraries that require OS support are not compatible with the device runtime.

The libraries within the table below are compatible with Weintek’s built-in Codesys. Libraries that do not require OS support are also compatible with Weintek’s built-in Codesys.; e.g. OSCAT Basic, Util library…etc.

Sys Library Cmp Library CAA Library
SysTimeRtc CmpTraceMgr CAAType
SysTimer

CmpSrv

CAATick
SysTime

CmpSettings

CAATickUtil
SysTask CmpSchedule CAAStorage
SysTarget CmpRouter
SysSocket CmpPlcShell
SysMem CmpLog
SysFile CmpIoMgr
SysExcept CmpIoDrvC
SysEvent CmpIecVarAccess
SysEthernet CmpIecTask
SysDir CmpEventMgr
SysCpuHandling CmpDynamicText
SysCom CmpCheckSum
CmpChannelServer
CmpBinTagUtilIec
CmpAsyncMgr
CmpAppBP

Note: An error message may appear on the Codesys IDE during “login” when adding an incompatible library in Weintek Codesys. Certain libraries may be able to be added to the Library Manager, but their function blocks may not be operational within POU. It would be recommended that users verify the Codesys logic before using any libraries & function blocks in production.

How much memory can be used in a Weintek’s Codesys project?

Here are some base level measurements for comparison:

Here are some base level measurements for comparison:

How much memory can be used in a Weintek’s Codesys project?

Here are the specs for reference: Data, Input, Output, Memory, Code Retain area 3 MB (Data persists after reboots)(Data is saved every 1 minute)Persistent area 16 KB (Data persists after downloads) (Data is saved every 1 minute) 16 KB File system 8 MB Note: 3MB for “Data, Input, Output, Memory, Code” is the max. size […]

Here are the specs for reference:

Data, Input, Output, Memory, Code
Retain area
3 MB
(Data persists after reboots)
(Data is saved every 1 minute)
Persistent area
16 KB
(Data persists after downloads)
(Data is saved every 1 minute)

16 KB
File system

8 MB

Note: 3MB for “Data, Input, Output, Memory, Code” is the max. size of a Weintek’s Codesys project (a file which is compiled by Codesys IDE and loaded into Weintek’s Codesys runtime). If the file size exceeds the capacity listed above, the following error message will display during compilation: “[ERROR] Out of code memory…No download possible”

Note: CODESYS firmware v20240703 have increased storage and memory space.

Note: When using CODESYS firmware is v20240703, please use CODESYS & Remote IO Package” 1.5.3.500 or later.

Data, Input, Output, Memory, Code
Retain area
5 MB
(Data persists after reboots)
(Data is saved every 1 minute)
Persistent area
32 KB
(Data persists after downloads)
(Data is saved every 1 minute)

32 MB
File system

12 MB

Can Weintek HMIs use Codesys Visulaization?

No. Weintek has been developing HMI software for 30+ years and we believe that we have the best HMI software available. Our EasyBuilder Pro software is Free and extensive in its capabilities.

No. Weintek has been developing HMI software for 30+ years and we believe that we have the best HMI software available. Our EasyBuilder Pro software is Free and extensive in its capabilities.

What is EasyAccess 2.0?

Weintek’s EasyAccess 2.0 is a remote access solution that provides a secure connection to your Weintek HMIs/devices without requiring any additional hardware. For detailed information, refer to this startup guide

Weintek’s EasyAccess 2.0 is a remote access solution that provides a secure connection to your Weintek HMIs/devices without requiring any additional hardware. For detailed information, refer to this startup guide

How do I activate Weintek’s EasyAccess 2.0?

To activate EasyAccess 2.0 on your device, please select a tutorial from the list below: How to add a cMT(X) series HMI to a Weincloud domain

To activate EasyAccess 2.0 on your device, please select a tutorial from the list below: How to add a cMT(X) series HMI to a Weincloud domain

How do I add users to a Weincloud/EasyAcess2.0 domain?

Different user roles are available within a Weincloud. Please watch this tutorial: How to add and configure users on a Weincloud domain

Different user roles are available within a Weincloud. Please watch this tutorial:

How to add and configure users on a Weincloud domain

Where can I download the EasyAccess 2.0 application?

To download the EasyAccess 2.0 application: Click Here

To download the EasyAccess 2.0 application: Click Here

How do I use EasyAccess 2.0?

To use the EasyAccess 2.0 application, please see this short tutorial: Click Here

To use the EasyAccess 2.0 application, please see this short tutorial: Click Here

How can I pass-through to my PLC?

To pass-through to an external device, please see this tutorial: Click Here

To pass-through to an external device, please see this tutorial: Click Here

Is EasyAccess 2.0 secure?

Security is one of our top priorities, communication between the EasyAccess 2.0 client (your PC) and the end device is encrypted using 256bit AES and 2048bit RSA encryption.

Security is one of our top priorities, communication between the EasyAccess 2.0 client (your PC) and the end device is encrypted using 256bit AES and 2048bit RSA encryption.

Are there any limitations

Each device with an active EasyAccess 2.0 license will be allotted 3 GB of high-speed data each month for free. This data can be used to update to the HMI or PLC or monitor the HMI using cMT-Viewer, VNC, or HMI Viewer. If the 3 GB threshold is exceeded in a given month the connection […]

Each device with an active EasyAccess 2.0 license will be allotted 3 GB of high-speed data each month for free. This data can be used to update to the HMI or PLC or monitor the HMI using cMT-Viewer, VNC, or HMI Viewer. If the 3 GB threshold is exceeded in a given month the connection speed will be throttled and a “snail” icon will be displayed. However, it must be stated that it is quite difficult to exceed this threshold.

What happens if I use all of my high-speed data

In the unlikely event that you exceed the allotted 3 GB of high-speed data, you may purchase a data top-up card through your supplier. Top-up cards will add an extra 5 GB or 10 GB of data to your domain, with one-year validity. When an HMI reaches its data cap for the month, the data […]

In the unlikely event that you exceed the allotted 3 GB of high-speed data, you may purchase a data top-up card through your supplier. Top-up cards will add an extra 5 GB or 10 GB of data to your domain, with one-year validity. When an HMI reaches its data cap for the month, the data from your top-up card will “kick in” and be consumed to maintain your high-speed connection.

What is Dashboard?

Dashboard is a cloud service that provides a simple and efficient way to monitor data from one or more HMIs. This service will allow applicable users and the domain admin to create and publish a webpage that can be configured to display both current and historical data.

Dashboard is a cloud service that provides a simple and efficient way to monitor data from one or more HMIs. This service will allow applicable users and the domain admin to create and publish a webpage that can be configured to display both current and historical data.

Is Dashboard compatible with my HMI?

Currently, Dashboard is compatible with any cMT-X HMI.

Currently, Dashboard is compatible with any cMT-X HMI.

How do I activate a Dashboard subscription?

To use Dashboard, please ensure that the HMI that will be used within your application has been added to your Weincloud domain. When finished, please perform the following: 1. Login to Weincloud. 2. Select the “Device” tab: 3.Click on the blue ‘i’ next to the HMI that you intend to activate: 4. Activate the HMI’s […]

To use Dashboard, please ensure that the HMI that will be used within your application has been added to your Weincloud domain. When finished, please perform the following:

1. Login to Weincloud.

2. Select the “Device” tab:

3.Click on the blue ‘i’ next to the HMI that you intend to activate:

4. Activate the HMI’s Dashboard license using an activation code:

What do I need to know in order to use Dashboard?

Creating a Dashboard project is easy! You do not need to be familiar with MQTT or EasyBuilder Pro. All that you need is a valid username and password on your Weincloud domain.

Creating a Dashboard project is easy! You do not need to be familiar with MQTT or EasyBuilder Pro. All that you need is a valid username and password on your Weincloud domain.

How do I create a Dashboard project?

To create your first Dashboard project, please see this tutorial: Click Here

To create your first Dashboard project, please see this tutorial: Click Here

How many data points can I publish from my device?

Each device can be configured to publish up to 100 (or 500 with expansion) different data points and the historical value of up to 20 (or 100 with expansion) points (per device) can be saved within your Weincloud domain.

Each device can be configured to publish up to 100 (or 500 with expansion) different data points and the historical value of up to 20 (or 100 with expansion) points (per device) can be saved within your Weincloud domain.

How often will the HMI publish data?

Data can be published to the cloud as often as every 1 seconds. However, this interval can be configured by the individual that develops the Dashboard project.

Data can be published to the cloud as often as every 1 seconds. However, this interval can be configured by the individual that develops the Dashboard project.

Can I download data that was published to Dashboard?

Absolutely! As long as “History” is enabled for the tag(s) that you would like to backup, Weincloud will store this data for 1 year. The file extension of the backup is .csv.

Absolutely! As long as “History” is enabled for the tag(s) that you would like to backup, Weincloud will store this data for 1 year. The file extension of the backup is .csv.

How can I access my Dashboard?

When the Dashboard project is published, it will be assigned a URL. The URL can be shared with anyone associated with the application or restricted to authorized personnel.

When the Dashboard project is published, it will be assigned a URL. The URL can be shared with anyone associated with the application or restricted to authorized personnel.

What protocols do your couplers support?

Can I use Weintek’s I/O without Codesys?

Yes, Weintek’s iR series remote I/O can be used with any device that supports the protocols mentioned above. However, please ensure that you choose the correct coupler for your application.

Yes, Weintek’s iR series remote I/O can be used with any device that supports the protocols mentioned above. However, please ensure that you choose the correct coupler for your application.

What is EasyRemote IO?

EasyRemote IO is an application that will allow you to configure the parameters of an iR-ETN or iR-ETN40R and connected IO modules. For more information, please see the EasyRemote IO user manual.

EasyRemote IO is an application that will allow you to configure the parameters of an iR-ETN or iR-ETN40R and connected IO modules. For more information, please see the EasyRemote IO user manual.

Where can I find information about I/O parameters?

The user manual that corresponds with the specified I/O module will contain a detailed description of the parameters found within EasyRemote IO. The aforementioned user manuals can be found within this post: Click Here In addition, we have created a table that contains all available project parameters and their description: Click Here“

The user manual that corresponds with the specified I/O module will contain a detailed description of the parameters found within EasyRemote IO. The aforementioned user manuals can be found within this post: Click Here
In addition, we have created a table that contains all available project parameters and their description: Click Here

How can I determine why the “ERR” light is on?

How can I determine why the “ERR” light is on? If you are using an iR-ETN or iR-ETN40R, you can monitor the I/O modules using EasyRemote IO via the following method: 1. Open EasyRemote IO and select the “Scan” button: 2. Within the following popup, click “Scan”: 3. When the scan is finished click “Ok” […]

How can I determine why the “ERR” light is on?
If you are using an iR-ETN or iR-ETN40R, you can monitor the I/O modules using EasyRemote IO via the following method:

1. Open EasyRemote IO and select the “Scan” button:

2. Within the following popup, click “Scan”:

3. When the scan is finished click “Ok” to add this device to the “Project window”:

4. Click on the “Start Monitoring” button to view the current values

5. A detailed description of the the module error will be shown within the message dialog:

For all other couplers, please consult the corresponding user manual for assistance.

Does each module need its own power source?

Yes, each module requires its own external power source.

Yes, each module requires its own external power source.

How many modules can I connect to one iR-ETN?

Note: Modules cannot be removed or connected to the device during runtime. This known as a “Hot-Swap” and is not supported by the iR-ETN, iR-ETN40R, or cMT-CTRL01.

Note: Modules cannot be removed or connected to the device during runtime. This known as a “Hot-Swap” and is not supported by the iR-ETN, iR-ETN40R, or cMT-CTRL01.

Why does the iR-DQ16-N have two UV/UG terminals?

Both the iR-DQ16-N and iR-DQ16-P have an extra set of UV & UG terminals that will allow you to supply power to another module. This method is illustrated within the example below:

Both the iR-DQ16-N and iR-DQ16-P have an extra set of UV & UG terminals that will allow you to supply power to another module. This method is illustrated within the example below:

How do you wire the iR-DM16-N?

Still need help?

Fill out the form on our contact page and a team member will get back to you. For additional support, check out our forum or email our support team at su*****@********sa.com