Build Smarter Machines with Integrated PLC Control
CODESYS Meets Industrial HMI
Reduce hardware, simplify programming, and accelerate machine development with Weintek's CODESYS-enabled HMIs. Run IEC 61131-3 PLC logic on a true RTOS directly on select Weintek cMT X Series HMIs while creating rich operator interfaces in EasyBuilder Pro.
Build Smarter Machines with Integrated PLC Control
CODESYS Meets Industrial HMI
Reduce hardware, simplify programming, and accelerate machine development with Weintek's CODESYS-enabled HMIs. Run IEC 61131-3 PLC logic on a true RTOS directly on select Weintek cMT X Series HMIs while creating rich operator interfaces in EasyBuilder Pro.
One Platform
Run PLC control and HMI visualization from the same device.
Open Connectivity
Communicate with hundreds of industrial devices while supporting modern industrial networks.
Lower Hardware Costs
Eliminate the need for a separate PLC in many machine applications.
Faster Development
Program machine logic in CODESYS while creating intuitive operator interfaces in EasyBuilder Pro.
Extend Your Machine Beyond the HMI
Use the CODESYS development environment to build your PLC logic, then create the operator experience in EasyBuilder Pro. This combination gives OEMs the flexibility of CODESYS control with Weintek’s full HMI and IIoT capabilities, including REST API integration, SQL connectivity, data logging, remote access, and support for 400+ industrial communication drivers.
EasyBuilder Pro gives you a flexible platform for connecting, monitoring, and managing your machine and its data.
Find the Right CODESYS-Enabled Weintek Solution
cMT X Standard
cMT X Advanced HMIs
Select cMT X Advanced HMIs combine 400+ communication protocols with advanced IIoT features like CAN Bus and SQL.
Faceless cMT X HMIs
Select cMT X Faceless HMIs combine compact DIN-rail design with easy remote control from any device.
Build Better HMIs with EasyBuilder Pro
CODESYS provides the PLC programming environment, while EasyBuilder Pro brings your machine to life with intuitive operator interfaces. Together, they create a complete automation solution that combines control, visualization, alarms, trending, recipes, data logging, and device communications—all designed to streamline development and simplify machine operation.
Whether you’re building a new machine or standardizing an existing platform, EasyBuilder Pro works seamlessly alongside CODESYS to help you develop, deploy, and maintain high-performance automation systems.
Build Your Next Machine with Confidence
Choosing the right hardware is just the beginning. From product selection and system architecture to CODESYS implementation and technical support, Weintek’s automation specialists are here to help at every stage of your project.
Whether you’re replacing legacy hardware, designing a new OEM platform, or expanding an existing system, we’ll help you identify the right combination of HMI, controller, remote I/O, and IIoT technologies to meet your application’s requirements.
Why CODESYS?
CODESYS is an exceptional PLC IDE that is the framework of many PLC IDEs on the market. If you have used Schneider, Beckhoff, or Wago’s PLC software you will find the CODESYS IDE quite familiar. In addition, the control logic complies with IEC 61131-3 which means that you can use ladder logic, function-block diagrams, sequential function charts, instruction lists, or structured text within your application.
Where can I download CODESYS?
Weintek’s R&D has validated CODESYS IDE v3.5.15.50 and related drivers for use with Weintek’s CODESYS-equipped HMIs or the cMT-CTRL-01. To download, please download CODESYS. Then log in to our Weintek Forum page, and install Weintek’s CODESYS package . After that you can review a short tutorial to create your first CODESYS application.
Can I remove Weintek’s CODESYS after activation?
On applicable cMT-X models it is possible to effectively disable CODESYS after activation. However, legacy HMIs do not have this capability.
Can I create my CODESYS project within EasyBuilder Pro?
No, you will need to use the CODESYS IDE (see above) to create your CODESYS project. The HMI can be programmed for visualization using EasyBuilder Pro. Note: Weintek’s CODESYS can only access Ethernet LAN-1 and CANBus port (if a CANBus port is embedded).
Can a CODESYS-activated HMI still use EasyAccess 2.0?
Can an HMI with CODESYS connect to devices in EasyBuilder Pro?
Yes, an HMI with CODESYS activated can still communicate with PLCs using any of the 400+ drivers available in EasyBuilder Pro—except for CAN bus on certain models. Once CODESYS is activated, it takes control of the CAN bus port. However, RS-232 and RS-485 ports remain available, and Ethernet-based PLCs can still be accessed via LAN 2, since LAN 1 is reserved for CODESYS.
How do I connect to Weintek's CODESYS?
CODESYS has complete control over LAN-1, please make sure that your PC is connected to LAN-1 or that you have “CODESYS Login” enabled on the HMI. While “CODESYS Login” is enabled, you can connect to the HMI and CODESYS using LAN-2. To enable CODESYS Login, please read this post: How to enable CODESYS login
Once finished specify the HMI’s LAN-2 IP within the “Device” communication setting in your CODESYS project. Note: CODESYS has no control over LAN-2.
What protocols does Weintek’s CODESYS support?
Currently Weintek’s built-in CODESYS supports the following protocols:
Modbus TCP/IP (master) |
EtherCAT (master) |
CANopen (master) |
Prerequisite: CANopen is only available on Weintek CMT-X HMIs that are equipped with a CANBus port. |
EtherNet/IP (master) |
PROFINET (master) |
Note: Weintek’s CODESYS cannot act as a Modbus TCP Slave by adding a single Modbus Slave device in the device tree, but users can utilize a specific Function Block of the ModbusTCPSlave library to achieve the objective.

What communication drivers should I use within CODESYS?
We recommend that you use device drivers included with Weintek’s CODESYS package:
| Device | Version |
|---|---|
| CANbus | 3.5.15.0 |
| CANopen manager | 3.5.15.0 |
| Ethernet adapter (added under Ethernet IP Scanner) | 3.5.15.0 |
| Ethernet IP Scanner | 3.5.15.50 |
| Modbus TCP maste | 3.5.15.0 |
| EtherCAT master | 3.5.12.0 |
| PROFINET master | 3.5.13.0 |
Note: You may need to select “Display all versions” within the “Add Device” dialog to select the appropriate driver. For more information, please read this post: How to update device drivers
How many devices can Weintek’s CODESYS communicate with?
| Modbus TCP/IP | 32 devices |
| EtherCAT | 65,535 devices |
| CANopen | 126 devices |
| EtherNet/IP | 32 devices |
| PROFINET | 32 devices |
What features cannot be used with Weintek’s CODESYS runtime?
OPC UA features
Network Variable List
Alarm Configuration (Alarm Manager)
Redundancy Configuration
CODESYS TargetVisu
CODESYS WebVisu
CODESYS HMI
SoftMotion
CODESYS IIoT Libraries SL
CODESYS OPC UA Client SL
CODESYS OPC UA Server SL
CODESYS Safety for EtherCAT Safety Module SL
Other add-ons
Trying to install other licenses from the CODESYS website will not work.
What libraries does Weintek’s CODESYS support?
“Weintek’s built-in CODESYS is compatible with wide range of built-in libraries. However, certain libraries that require OS support are not compatible with the device runtime.
The libraries within the table below are compatible with Weintek’s built-in CODESYS. Libraries that do not require OS support are also compatible with Weintek’s built-in CODESYS.; e.g. OSCAT Basic, Util library…etc.
| Sys Library | Cmp Library | CAA Library |
|---|---|---|
| SysTimeRtc | CmpTraceMgr | CAAType |
| SysTimer | CmpSrv | CAATick |
| SysTime | CmpSettings | CAATickUtil |
| SysTask | CmpSchedule | CAAStorage |
| SysTarget | CmpRouter | |
| SysSocket | CmpPlcShell | |
| SysMem | CmpLog | |
| SysFile | CmpIoMgr | |
| SysExcept | CmpIoDrvC | |
| SysEvent | CmpIecVarAccess | |
| SysEthernet | CmpIecTask | |
| SysDir | CmpEventMgr | |
| SysCpuHandling | CmpDynamicText | |
| SysCom | CmpCheckSum | |
| CmpChannelServer | ||
| CmpBinTagUtilIec | ||
| CmpAsyncMgr | ||
| CmpAppBP |
Note: An error message may appear on the CODESYS IDE during “login” when adding an incompatible library in Weintek CODESYS. Certain libraries may be able to be added to the Library Manager, but their function blocks may not be operational within POU. It would be recommended that users verify the CODESYS logic before using any libraries & function blocks in production.
How much memory can be used in a Weintek CODESYS project?
Here are the specs for reference:
| Data, Input, Output, Memory, Code Retain area | 3 MB |
|---|---|
| (Data persists after reboots) (Data is saved every 1 minute) Persistent area | 16 KB |
| (Data persists after downloads) (Data is saved every 1 minute) | 16 KB |
| File system | 8 MB |
Note: 3MB for “Data, Input, Output, Memory, Code” is the max. size of a Weintek’s CODESYS project (a file which is compiled by CODESYS IDE and loaded into Weintek’s CODESYS runtime). If the file size exceeds the capacity listed above, the following error message will display during compilation: “[ERROR] Out of code memory…No download possible”
Note: CODESYS firmware v20240703 have increased storage and memory space.
Note: When using CODESYS firmware is v20240703, please use CODESYS & Remote IO Package” 1.5.3.500 or later.
| Data, Input, Output, Memory, Code Retain area | 5 MB |
|---|---|
| (Data persists after reboots) (Data is saved every 1 minute) Persistent area | 32 KB |
| (Data persists after downloads) (Data is saved every 1 minute) | 32 MB |
| File system | 12 MB |